Technical specifications

  • Technical requirements

    Materials

    • TIMBER: Timber in accordance with standard UNE-EN-386 “Glued laminated timber. Manufacturing specifications and requirements”.
    • ADHESIVES: In accordance with standard UNE-EN-301 “Phenolic and aminoplastic adhesives for use in structures”.
    • IRON FITTINGS: Hot dip galvanised iron fittings.

    Manufacturing

    Manufacturing in accordance with Standard UNE-EN-386.
    Manufacturer subjected to AITIM external control.
    AITIM - 15 Quality Seal.

    Calculation, design and installation.

    In accordance with Standard DIN-1052. - ENV 1995.
    Calculation, design and installation, subject to AITIM external control.
    AITIM - 22 Quality Seal.

    Wood preventive protection treatment.

    The necessary fungicide-insecticide treatments in accordance with the structure’s type of use will be applied, in accordance with standard UNE-EN 335-1.

    Control tests.

    Internal and external control tests on the manufacturer in accordance with the following standards:

    • UNE-EN-385 “Structural wood with groove joints. Manufacturing requirements”.
    • UNE-EN-392 “Glued laminated timber. Glue line shear test”.
    • UNE-EN-408 “Groove joint bending test”.

  • Information for a study

    Prescriber’s details

      Architect, Engineer, ..., Others:
      Name:
      Surnames:
      E-mail:
      Tel. no.:
      Fax:
      Full address:

    Project / Works

      Site address:
      Site location:

    Dimensioned floor plan of the structure, with location of main and secondary beams.

    Plan of structure support points.

    Cross section or sections defining the structure’s formal layout.

    Cover materials and loads per m2

    Example:
      22mm terrace... 12 kg/m2
      Vapour barrier-Roof felt... 5 kg/m2
      Rigid insulation... 5 kg/m2
      Double battening and ceramic tiles... 60 kg/m2
      Struts... 5 kg/m2

    Climate loads

      Snow: Topographical altitude or kg/m2 of snow.
      Wind: Dynamic pressure in kg/m2 or maximum wind speed

    Maintenance loads

      Example: 100 kg point load at any specific location on the roof.

    Fire stability

      Example: F.S. = 30 min.
  • Pre-dimensioning
    STRUCTURAL
    SYSTEM
      Roof
    slope
    Separation m Common
    clearances m
    Pre-dimensioning
    Deep beam.
    Curved-straight intrados
    (ends of edge constant)
    5-15 5-7 5-7 10-35 h=L/30
    H=L/15

    Download complete table of examples

  • Dimensioning of straight beams